eONPUIR

Damage to Steam Turbine Rotors Due to Asynchronous Connections of Electric Generators to the Unified Power System

Показать сокращенную информацию

dc.contributor.author Chernousenko, O.Yu.
dc.contributor.author Marysiuk, B.A.
dc.date.accessioned 2025-05-18T18:10:45Z
dc.date.available 2025-05-18T18:10:45Z
dc.date.issued 2024
dc.identifier.citation Chernousenko O. Damage to Steam Turbine Rotors Due to Asynchronous Connections of Electric Generators to the Unified Power System / O. Chernousenko, B. Marysiuk // Problems of the Regional Energetics, (4), 2024. - 127-134. en
dc.identifier.uri http://dspace.opu.ua/jspui/handle/123456789/15218
dc.description.abstract The article aims to contribute to the ongoing study of damage to steam turbine rotors resulting from asynchronous connection of electric generators to the unified power system. At the present time, the assessment of the residual life of steam turbine equipment is based on the study of the degradation of the mechanical properties of steels and the analysis of the thermal stress state. The aim of this work was to determine the impact of such vibrations on the mechanical properties of rotors and their damage. This goal was achieved by solving the following tasks: developing a 3D model of the K-1000-60/3000 LMZ turbine unit shaft based on design documentation; calculating the stress-strain state of the shaft resulting from asynchronous connections using finite element analysis; and evaluating the level of metal damage in the rotors due to torsional vibrations. The developed mathematical model used a classical approach, replacing the working blades and bandage fastenings with concentrated masses and moments of inertia. The most important results are the calculated rotor damages that occur due to asynchronous connection of the turbogenerator to the unified power system with a synchronization angle of 30°. The greatest damage to the rotor metal was found in the shaft section between the steam turbine and the electric generator. The significance of the results obtained is that the use of this data will improve methods for assessing the remaining life of turbogenerators. This, in turn, will improve the reliability and safety of power plant operations. en
dc.language.iso en_US en
dc.subject steam turbine en
dc.subject rotor en
dc.subject asynchronous connection en
dc.subject torsional vibrations en
dc.subject stress-strain state en
dc.subject damage en
dc.title Damage to Steam Turbine Rotors Due to Asynchronous Connections of Electric Generators to the Unified Power System en
dc.type Article en
opu.citation.firstpage 127 en
opu.citation.lastpage 134 en


Файлы, содержащиеся в элементе

Этот элемент содержится в следующих коллекциях

Показать сокращенную информацию