eONPUIR

Analysis of nuclear safety in diversification of Westinghouse fuel assemblies at WWER-1000

Показать сокращенную информацию

dc.contributor.author Скалозубов, Владимир Иванович
dc.contributor.author Козлов, Игорь Леонидович
dc.contributor.author Комаров, Юрий Алексеевич
dc.contributor.author Чулкин, Олег Александрович
dc.contributor.author Пионтковский, Алексей ru
dc.contributor.author Скалозубов, Володимир Іванович uk
dc.contributor.author Skalozubov, Volodymyr en
dc.contributor.author Kozlov, Ihor en
dc.contributor.author Козлов, Ігор Леонидович uk
dc.contributor.author Комаров, Юрій Олексійович uk
dc.contributor.author Komarov, Urii en
dc.contributor.author Піонтковський, Олексій Ігорович, uk
dc.contributor.author Piontkovskyi, Oleksii en
dc.contributor.author Чулкін, Олег Олександрович uk
dc.contributor.author Сhulkin, Оleg en
dc.date.accessioned 2019-12-06T06:46:02Z
dc.date.available 2019-12-06T06:46:02Z
dc.date.issued 2019-12-02
dc.identifier.citation Analysis of nuclear safety in diversification of Westinghouse fuel assemblies at WWER-1000 / V. I. Skalozubov, I. L. Kozlov, Yu. A. Komarov, O. A. Chulkin, O. I. Piontkovskyi // Ядерна фізика та енергетика. – 2019. – Vol. 20, N 2. – P. 159–163. en
dc.identifier.citation Skalozubov, V. I., Kozlov, I. L., Komarov,Yu. A., Chulkin, O. A., Piontkovskyi, O. I. (2019). Analysis of nuclear safety in diversification of Westinghouse fuel assemblies at WWER-1000. Nuclear Physics and Atomic Energy, 20, 2,159–163. en
dc.identifier.issn 1818-331X
dc.identifier.uri http://dspace.opu.ua/jspui/handle/123456789/9848
dc.description.abstract The research presents an analysis of the known results in modeling the maximum design accident (MDA) using the code RELAP5/V3.2 whith Westinghouse fuel assemblies’ (WFA) diversification in WWER-1000 reactors. According to the known results of MDA calculated model simulation with RELAP5/V3.2 code at the maximum allowable water temperature in the heat WWER emergency cooling system exchanger (90 ºС), the fuel elements’ claddings temperature reaches 1320 ºС and exceeds the admissible nuclear safety limit (1200 ºС). Thus, according to known results, these MDA whith WFA engaged pass from the “design” accident status to the “severe” acciden status and means a decrease in safety in relation to the FA-A fuel assemblies. The alternative MDA analysis for WFA-equipped plants showed that, unlike the known calculations, the nuclear safety limit on the maximum permissible fuel cladding temperature is not violated and never reduces the overall safety level in WWER diversification with WFA fuel assemblies. en
dc.language.iso en en
dc.publisher Institute for Nuclear Research of the National Academy of Sciences of Ukraine en
dc.subject security en
dc.subject diversification of fuel assemblies en
dc.title Analysis of nuclear safety in diversification of Westinghouse fuel assemblies at WWER-1000 en
dc.type Article in Web of Science en
opu.kafedra Кафедра теплових електричних станцій та енергозберігаючих технологій uk
opu.citation.journal Ядерна фізика та енергетика en
opu.citation.volume 20 en
opu.citation.firstpage 159 en
opu.citation.lastpage 163 en