Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://dspace.opu.ua/jspui/handle/123456789/13905
Название: Computer simulation of the microprocessor liquid level automatic control system
Другие названия: Комп’ютерне моделювання мікропроцесорної системи автоматичного контролю рівня рідини
Авторы: Nazarova, Olena
Назарова, Олена Сергіївна
Назарова, Елена Сергеевна
Osadchyy, Volodymyr
Осадчий, Володимир Володимирович
Осадчий, Владимир Владимирович
Rudim, Bohdan
Рудім, Богдан Юрійович
Рудим, Богдан Юрьевич
Ключевые слова: Automatic control system
liquid level
microprocessor
computer simulation
pi controller
optimization
Дата публикации: 3-Июл-2023
Издательство: Nauka i Tekhnika
Библиографическое описание: Nazarova, O., Osadchyy, V., Rudim, B. (2023). Computer simulation of the microprocessor liquid level automatic control system. Аpplied Aspects of Information Technology, Vol. 6, N 2, р. 163–174.
Nazarova, O. Computer simulation of the microprocessor liquid level automatic control system / O. Nazarova, V. Osadchyy, B. Rudim // Аpplied Aspects of Information Technology = Прикладні аспекти інформ. технологій. – Оdesa, 2023. – Vol. 6, N 2. – P. 163–174.
Краткий осмотр (реферат): Today, automation occupies a leading place in most branches of modern society, in almost all types of industry and economy. One of the main tasks of designing modern automatic control systems is the realization of high indicators in terms of accuracy, control range, and speed, taking into account the features of the control object itself. The purpose of the work –researching the microprocessor system of automatic control of the liquid level by means of computer modeling, taking into account the transport delay, the nonlinearity of the control characteristic of the pump and the presence of an insensitivity zone. To achieve the goal, the following tasks were solved: a computer model of a closed microprocessor system for automatic control of the liquid level wasdeveloped, taking into account the nonlinearity of the characteristics of the pumping unit and transport delay; a number of experiments were conducted to find the values of PI-regulator coefficients that bring the transient process of a real system with a transport delay as close as possible to the transient process of a system in which there is no transport delay; search for optimal values of the coefficients of the PI controller by minimizing the functional of the root mean square deviation of the real from the specified transient processes. As a result of research, it was established that the minimum points of the functional for the control signal and the liquid level do not coincide. At the same time, at the minimum point of the functional for the liquid level, a larger amplitude of oscillations of the control signal is observed, and at the minimum point of the functional for the control signal –an increase in the duration of the transient process. Therefore, the final decision should be based on the selection of priorities or optimal ratios between the speed and wear of the equipment, which is due tothe instability of the control signal.
URI (Унифицированный идентификатор ресурса): http://dspace.opu.ua/jspui/handle/123456789/13905
ISSN: 2617-4316
2663-7723
Располагается в коллекциях:2023, Vol. 6, № 2

Файлы этого ресурса:
Файл Описание РазмерФормат 
184-Article Text-420-3-10-20230705.pdf1.15 MBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.