Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
http://dspace.opu.ua/jspui/handle/123456789/13965
Название: | Reliability control of a thermoelectric cooler with changes in ambient temperature |
Другие названия: | Управління показниками надійності однокаскадного термоелектричного охолоджувача при зміні температури середовища |
Авторы: | Zaykov, Vladimir Зайков, Володимир Петрович Mescheryakov, Vladimir Мещеряков, Володимир Іванович Zhuravlov, Yurii Журавльов, Юрій Іванович |
Ключевые слова: | Thermoelectric cooler dynamic characteristics reliability index control medium temperature thermal mode |
Дата публикации: | 3-Июл-2023 |
Издательство: | Nauka i Tekhnika |
Библиографическое описание: | Zaykov, V., Mescheryakov, V., Zhuravlov, Yu. (2023). Reliability control of a thermoelectric cooler with changes in ambient temperature. Herald of Advanced Information Technology, Vol. 6, N 2, р. 152–162. Zaykov, V. Reliability control of a thermoelectric cooler with changes in ambient temperature / V. Zaykov, V. Mescheryakov, Yu. Zhuravlov // Herald of Advanced Information Technology = Вісн. сучас. інформ. технологій. – Оdesa, 2023. – Vol. 6, N 2. – Р. 152–162. |
Краткий осмотр (реферат): | The paper presents the development of method of thermoelectric system reliability indexes control for providing thermal modes of radio electronic equipment, based on thermoelectric coolers medium temperature variation. A mathematical model for investigating influence of the environment temperature variation on the reliability performance of a single-cascade thermoelectric cooler at a given temperature level of cooling, thermal load, geometry of thermoelement branches for different characteristic current operating modes is considered. The results of calculations of the basic parameters, reliability indices, dynamic characteristics and the analysis of dependences are given for revealing the peculiarities of control processes. It is shown that decreasing the medium temperature at a given chiller design decreases the operating current, increases the cold-productivity, and decreases the time of reaching a steady-state operating mode for various characteristic current operating modes. The time to steady-state operation decreases from the minimum failure rate to the maximum cooling capacity at a fixed medium temperature. The minimum steadystate operation time is ensured in maximum cooling capacity mode. Reduction of such significant for control indices as the amount of consumed energy for different characteristic current operation modes, required heat dissipation capacity of the radiator, time of reaching the steady-state mode is noted. Analysis of research results has shown that it is possible to control indicators of reliability of a single-stage cooler of a given design by changing the medium temperature by changing the value of operating current. A change in the medium temperature of the thermoelectric cooler due to an external supporting device makes it possible to vary the reliability indices and to find a compromise between the reliability, dynamics and cooling capacity of the thermal mode support system |
URI (Унифицированный идентификатор ресурса): | http://dspace.opu.ua/jspui/handle/123456789/13965 |
ISSN: | 2663-0176 2663-7731 |
Располагается в коллекциях: | 2023, Vol. 6, № 2 |
Файлы этого ресурса:
Файл | Описание | Размер | Формат | |
---|---|---|---|---|
164-Article Text-211-1-10-20230709.pdf | 1.49 MB | Adobe PDF | Просмотреть/Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.