Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://dspace.opu.ua/jspui/handle/123456789/6312
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorDenisova, Alla-
dc.contributor.authorДенисова, Алла Євсіївна-
dc.contributor.authorДенисова, Алла Евсеевна-
dc.date.accessioned2017-12-09T09:31:03Z-
dc.date.available2017-12-09T09:31:03Z-
dc.date.issued2016-12-
dc.identifier.citationDenisova, A. (2016). Two-stage heat pump installations for heat supply. Project, Program, Portfolio p3 Management : the first International scientific-practical conference, Ukraine, Odesa, 16-17 december 2016, Vol. 2, p. 40-43.en
dc.identifier.citationDenisova, A. Two-stage heat pump installations for heat supply / A. Denisova // Project, Program, Portfolio p3 Management : the first International scientific-practical conference, Ukraine, Odesa, 16-17 december 2016. - Odesa, 2016. - Vol. 2. - P. 40-43.en
dc.identifier.isbn978-617-7424-18-4-
dc.identifier.urihttp://dspace.opu.ua/jspui/handle/123456789/6312-
dc.description.abstractAbstract: The problem of energy saving becomes one of the most important in power engineering. It is caused by exhaustion of world reserves in hydrocarbon fuel, such as gas, oil and coal representing sources of traditional heat supply. Conventional sources have essential shortcomings: low power, ecological and economic efficiencies, that can be eliminated by using alternative methods of power supply, like the considered one: low-temperature natural heat of ground waters of on the basis of heat pump installations application. The heat supply system considered provides an effective use of two stages heat pump installation operating as heat source at ground waters during the lowest ambient temperature period. Proposed is a calculation method of heat pump installations on the basis of groundwater energy. Calculated are the values of electric energy consumption by the compressors’ drive, and the heat supply system transformation coefficient µ for a low-potential source of heat from ground waters allowing to estimate high efficiency of two stages heat pump installations.en
dc.language.isoen_USen
dc.publisherІКС ОНПУen
dc.subjectheating loadingen
dc.subjectfreonen
dc.subjecttwo stages heat pump installationen
dc.subjectlow-potential source of heaten
dc.subjectenergy efficiencyen
dc.titleTwo-stage heat pump installations for heat supplyen
dc.typeConference proceedingsen
opu.kafedraКафедра теплових електричних станцій та енергозберігаючих технологійuk
opu.citation.volume2en
opu.citation.firstpage40en
opu.citation.lastpage43en
opu.citation.conferenceProject, Program, Portfolio Management. P3Men
opu.conference.dates16-17 декабря 2016 годаen
Располагается в коллекциях:Конференции
Конференции
Матеріали конференцій, семінарів каф. ТЕСЕТ
Project, Program, Portfolio Management. P3M - 2016

Файлы этого ресурса:
Файл Описание РазмерФормат 
TWO-STAGE HEAT PUMP INSTALLATIONS FOR HEAT SUPPLY .pdf711.73 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.