Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://dspace.opu.ua/jspui/handle/123456789/9848
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorСкалозубов, Владимир Иванович-
dc.contributor.authorКозлов, Игорь Леонидович-
dc.contributor.authorКомаров, Юрий Алексеевич-
dc.contributor.authorЧулкин, Олег Александрович-
dc.contributor.authorПионтковский, Алексейru
dc.contributor.authorСкалозубов, Володимир Івановичuk
dc.contributor.authorSkalozubov, Volodymyren
dc.contributor.authorKozlov, Ihoren
dc.contributor.authorКозлов, Ігор Леонидовичuk
dc.contributor.authorКомаров, Юрій Олексійовичuk
dc.contributor.authorKomarov, Uriien
dc.contributor.authorПіонтковський, Олексій Ігорович,uk
dc.contributor.authorPiontkovskyi, Oleksiien
dc.contributor.authorЧулкін, Олег Олександровичuk
dc.contributor.authorСhulkin, Оlegen
dc.date.accessioned2019-12-06T06:46:02Z-
dc.date.available2019-12-06T06:46:02Z-
dc.date.issued2019-12-02-
dc.identifier.citationAnalysis of nuclear safety in diversification of Westinghouse fuel assemblies at WWER-1000 / V. I. Skalozubov, I. L. Kozlov, Yu. A. Komarov, O. A. Chulkin, O. I. Piontkovskyi // Ядерна фізика та енергетика. – 2019. – Vol. 20, N 2. – P. 159–163.en
dc.identifier.citationSkalozubov, V. I., Kozlov, I. L., Komarov,Yu. A., Chulkin, O. A., Piontkovskyi, O. I. (2019). Analysis of nuclear safety in diversification of Westinghouse fuel assemblies at WWER-1000. Nuclear Physics and Atomic Energy, 20, 2,159–163.en
dc.identifier.issn1818-331X-
dc.identifier.urihttp://dspace.opu.ua/jspui/handle/123456789/9848-
dc.description.abstractThe research presents an analysis of the known results in modeling the maximum design accident (MDA) using the code RELAP5/V3.2 whith Westinghouse fuel assemblies’ (WFA) diversification in WWER-1000 reactors. According to the known results of MDA calculated model simulation with RELAP5/V3.2 code at the maximum allowable water temperature in the heat WWER emergency cooling system exchanger (90 ºС), the fuel elements’ claddings temperature reaches 1320 ºС and exceeds the admissible nuclear safety limit (1200 ºС). Thus, according to known results, these MDA whith WFA engaged pass from the “design” accident status to the “severe” acciden status and means a decrease in safety in relation to the FA-A fuel assemblies. The alternative MDA analysis for WFA-equipped plants showed that, unlike the known calculations, the nuclear safety limit on the maximum permissible fuel cladding temperature is not violated and never reduces the overall safety level in WWER diversification with WFA fuel assemblies.en
dc.language.isoenen
dc.publisherInstitute for Nuclear Research of the National Academy of Sciences of Ukraineen
dc.subjectsecurityen
dc.subjectdiversification of fuel assembliesen
dc.titleAnalysis of nuclear safety in diversification of Westinghouse fuel assemblies at WWER-1000en
dc.typeArticle in Web of Scienceen
opu.kafedraКафедра теплових електричних станцій та енергозберігаючих технологійuk
opu.citation.journalЯдерна фізика та енергетикаen
opu.citation.volume20en
opu.citation.firstpage159en
opu.citation.lastpage163en
opu.citation.issue2en