eONPUIR

Computer simulation of the microprocessor liquid level automatic control system

Показать сокращенную информацию

dc.contributor.author Nazarova, Olena
dc.contributor.author Назарова, Олена Сергіївна
dc.contributor.author Назарова, Елена Сергеевна
dc.contributor.author Osadchyy, Volodymyr
dc.contributor.author Осадчий, Володимир Володимирович
dc.contributor.author Осадчий, Владимир Владимирович
dc.contributor.author Rudim, Bohdan
dc.contributor.author Рудім, Богдан Юрійович
dc.contributor.author Рудим, Богдан Юрьевич
dc.date.accessioned 2023-07-07T13:12:11Z
dc.date.available 2023-07-07T13:12:11Z
dc.date.issued 2023-07-03
dc.identifier.citation Nazarova, O., Osadchyy, V., Rudim, B. (2023). Computer simulation of the microprocessor liquid level automatic control system. Аpplied Aspects of Information Technology, Vol. 6, N 2, р. 163–174. еn
dc.identifier.citation Nazarova, O. Computer simulation of the microprocessor liquid level automatic control system / O. Nazarova, V. Osadchyy, B. Rudim // Аpplied Aspects of Information Technology = Прикладні аспекти інформ. технологій. – Оdesa, 2023. – Vol. 6, N 2. – P. 163–174. еn
dc.identifier.issn 2617-4316
dc.identifier.issn 2663-7723
dc.identifier.uri http://dspace.opu.ua/jspui/handle/123456789/13905
dc.description.abstract Today, automation occupies a leading place in most branches of modern society, in almost all types of industry and economy. One of the main tasks of designing modern automatic control systems is the realization of high indicators in terms of accuracy, control range, and speed, taking into account the features of the control object itself. The purpose of the work –researching the microprocessor system of automatic control of the liquid level by means of computer modeling, taking into account the transport delay, the nonlinearity of the control characteristic of the pump and the presence of an insensitivity zone. To achieve the goal, the following tasks were solved: a computer model of a closed microprocessor system for automatic control of the liquid level wasdeveloped, taking into account the nonlinearity of the characteristics of the pumping unit and transport delay; a number of experiments were conducted to find the values of PI-regulator coefficients that bring the transient process of a real system with a transport delay as close as possible to the transient process of a system in which there is no transport delay; search for optimal values of the coefficients of the PI controller by minimizing the functional of the root mean square deviation of the real from the specified transient processes. As a result of research, it was established that the minimum points of the functional for the control signal and the liquid level do not coincide. At the same time, at the minimum point of the functional for the liquid level, a larger amplitude of oscillations of the control signal is observed, and at the minimum point of the functional for the control signal –an increase in the duration of the transient process. Therefore, the final decision should be based on the selection of priorities or optimal ratios between the speed and wear of the equipment, which is due tothe instability of the control signal. en
dc.language.iso en en
dc.publisher Nauka i Tekhnika en
dc.subject Automatic control system en
dc.subject liquid level en
dc.subject microprocessor en
dc.subject computer simulation en
dc.subject pi controller en
dc.subject optimization en
dc.title Computer simulation of the microprocessor liquid level automatic control system en
dc.title.alternative Комп’ютерне моделювання мікропроцесорної системи автоматичного контролю рівня рідини uk
dc.type Article en
opu.citation.journal Applied Aspects of Information Technology en
opu.citation.volume 2 en
opu.citation.firstpage 163 en
opu.citation.lastpage 174 en
opu.citation.issue 6 en


Файлы, содержащиеся в элементе

Этот элемент содержится в следующих коллекциях

Показать сокращенную информацию