eONPUIR

Reliability control of a thermoelectric cooler with changes in ambient temperature

Показать сокращенную информацию

dc.contributor.author Zaykov, Vladimir
dc.contributor.author Зайков, Володимир Петрович
dc.contributor.author Mescheryakov, Vladimir
dc.contributor.author Мещеряков, Володимир Іванович
dc.contributor.author Zhuravlov, Yurii
dc.contributor.author Журавльов, Юрій Іванович
dc.date.accessioned 2023-07-13T21:09:37Z
dc.date.available 2023-07-13T21:09:37Z
dc.date.issued 2023-07-03
dc.identifier.citation Zaykov, V., Mescheryakov, V., Zhuravlov, Yu. (2023). Reliability control of a thermoelectric cooler with changes in ambient temperature. Herald of Advanced Information Technology, Vol. 6, N 2, р. 152–162. еn
dc.identifier.citation Zaykov, V. Reliability control of a thermoelectric cooler with changes in ambient temperature / V. Zaykov, V. Mescheryakov, Yu. Zhuravlov // Herald of Advanced Information Technology = Вісн. сучас. інформ. технологій. – Оdesa, 2023. – Vol. 6, N 2. – Р. 152–162. еn
dc.identifier.issn 2663-0176
dc.identifier.issn 2663-7731
dc.identifier.uri http://dspace.opu.ua/jspui/handle/123456789/13965
dc.description.abstract The paper presents the development of method of thermoelectric system reliability indexes control for providing thermal modes of radio electronic equipment, based on thermoelectric coolers medium temperature variation. A mathematical model for investigating influence of the environment temperature variation on the reliability performance of a single-cascade thermoelectric cooler at a given temperature level of cooling, thermal load, geometry of thermoelement branches for different characteristic current operating modes is considered. The results of calculations of the basic parameters, reliability indices, dynamic characteristics and the analysis of dependences are given for revealing the peculiarities of control processes. It is shown that decreasing the medium temperature at a given chiller design decreases the operating current, increases the cold-productivity, and decreases the time of reaching a steady-state operating mode for various characteristic current operating modes. The time to steady-state operation decreases from the minimum failure rate to the maximum cooling capacity at a fixed medium temperature. The minimum steadystate operation time is ensured in maximum cooling capacity mode. Reduction of such significant for control indices as the amount of consumed energy for different characteristic current operation modes, required heat dissipation capacity of the radiator, time of reaching the steady-state mode is noted. Analysis of research results has shown that it is possible to control indicators of reliability of a single-stage cooler of a given design by changing the medium temperature by changing the value of operating current. A change in the medium temperature of the thermoelectric cooler due to an external supporting device makes it possible to vary the reliability indices and to find a compromise between the reliability, dynamics and cooling capacity of the thermal mode support system en
dc.language.iso en_US en
dc.publisher Nauka i Tekhnika en
dc.subject Thermoelectric cooler en
dc.subject dynamic characteristics en
dc.subject reliability index control en
dc.subject medium temperature en
dc.subject thermal mode en
dc.title Reliability control of a thermoelectric cooler with changes in ambient temperature en
dc.title.alternative Управління показниками надійності однокаскадного термоелектричного охолоджувача при зміні температури середовища en
dc.type Article en
opu.citation.journal Herald of Advanced Information Technology en
opu.citation.volume 6 en
opu.citation.firstpage 152 en
opu.citation.lastpage 162 en
opu.citation.issue 2 en
opu.staff.id http://orcid.org/0000-0001-7342-1031 en
opu.staff.id http://orcid.org/0000-0003-0499-827X en
opu.staff.id http://orcid.org/0000-0002-4078-3519 en


Файлы, содержащиеся в элементе

Этот элемент содержится в следующих коллекциях

Показать сокращенную информацию