Обоснование выбора схемного решения и геометрических параметров СПОТ ГО ВВЭР-1000

Показать сокращенную информацию

dc.contributor.author Наффаа Х. М.
dc.contributor.author Naffaa Kh. M.
dc.contributor.author Дубковский, Вячеслав Александрович
dc.contributor.author Дубковський, В`ячеслав Олександрович
dc.contributor.author Dubkovskyi, Viacheslav
dc.date.accessioned 2017-03-03T09:14:01Z
dc.date.available 2017-03-03T09:14:01Z
dc.date.issued 2014-06
dc.identifier.citation Наффаа Х. М. Обоснование выбора схемного решения и геометрических параметров СПОТ ГО ВВЭР-1000 / Наффаа Х. М., В. А. Дубковский // Ядерна та радіац. безпека. - 2014. - № 3 (63). - С. 19-23. ru
dc.identifier.issn 2073-6237
dc.identifier.uri http://sstc.kiev.ua/documents/journal/2014/3/4_3_2014_text.pdf
dc.identifier.uri http://dspace.opu.ua/xmlui/handle/123456789/1474
dc.description.abstract Обосновывается выбор схемного решения и геометрических параметров системы пассивного отвода тепла от герметичной оболочки (СПОТ ГО) ВВЭР-1000 на основе двухфазного термосифона. Выполнено расчетное моделирование контура СПОТ ГО с использованием теплогидравлического кода RELAP5/MOD3.4. Рассмотрены и проанализированы три варианта термосифона: ординарный двухфазный, с L-образной трубой, кольцевой двухфазный; степень заполнения контура варьировалась от 0,1 до 0,8, угол наклона — от 5 до 90°. Расчеты проводились как для трубчатых, так и для пластинчатых поверхностей теплообмена en
dc.description.abstract Обгрунтовується вибір схемного рішення та геометричних параметрів системи пасивного відведення тепла від захисної оболонки (СПВТ ГО) ВВЕР-1000 на основі двофазного термосифона, таких як ступінь заповнення контуру, кут нахилу й геометрія елементів системи. Виконано розрахункове моделювання контуру СПВТ ГО з використанням теплогідравлічного коду RELAP5/MOD3.4. Розглянуто й проаналізовано три варіанти термосифона: ординарний двофазний, з L-подібної трубою, кільцевий двофазний; ступінь заповнення контуру варіювався від 0,1 до 0.8, кут нахилу — від 5 до 90°. Розрахунки проводилися як для трубчастих, так і для пластинчастих поверхонь теплообміну en
dc.description.abstract The closed-type evaporation-condensation device based on a low-temperature two-phase annular thermosyphon is one of the most efficient containment cooling systems for new generation of WWER-1000 reactors. This system provides efficient heat transfer from the containment to the ultimate heat sink through transfer of the latent heat caused by steam generation. The evaporator is located inside the containment and the condenser is placed beyond it. The evaporator and condenser are interconnected by steam and condensate piping. The paper is aimed at justification of circuit design and geometric parameters (filling ratio, inclination angle, geometry of system components) of the passive heat removal system for WWER-1000 containment (C-PHRS) based on a two-phase thermosyphon. The C-PHRS circuit was modeled by means of the RELA5/MOD3.4 thermohydraulic code. Three types of thermosyphons were reviewed and analyzed: ordinary two-phased, L-shaped pipe, and twophase closed thermosyphons. The filling ratio ranged from 0.1 to 0.8 and the inclination angle ranged from 5 to 90 deg. Calculations were performed for both tubular and plate heat-exchange surfaces. en
dc.language.iso ru en
dc.subject система пассивного отвода тепла en
dc.subject защитная оболочка en
dc.subject двухфазный термосифон en
dc.subject атомная электрическая станция en
dc.subject реакторная установка en
dc.subject водо-водяной энергетический реактор en
dc.subject система пасивного відводу тепла en
dc.subject захисна оболонка en
dc.subject двофазний термосифон en
dc.subject атомна електрична станція en
dc.subject реакторна установка en
dc.subject водо-водяний енергетичний реактор en
dc.subject passive heat removal system (PHRS) en
dc.subject containment en
dc.subject two-phase thermosyphon en
dc.subject nuclear power plant (NPP) en
dc.subject reactor facility en
dc.subject WWER en
dc.title Обоснование выбора схемного решения и геометрических параметров СПОТ ГО ВВЭР-1000 en
dc.title.alternative Обгрунтування вибору схемного рішення і геометричних параметрів СПВТ ГО ВВЕР-1000 en
dc.title.alternative Justification of Circuit Design and Geometric Parameters of C-PHRS for WWER-1000 en
dc.type Article en
opu.kafedra Кафедра атомних електричних станцій uk
opu.citation.journal Ядерна та радіаційна безпека en
opu.citation.firstpage 19 en
opu.citation.lastpage 23 en