eONPUIR

Експериментальні дослідження взаємних впливів між провідниками трифазного кабелю

Показать сокращенную информацию

dc.contributor.author Маєвський, Дмитро Андрійович
dc.contributor.author Яковлев, О. В.
dc.contributor.author Морозов, О. П.
dc.contributor.author Топузанов, О. О.
dc.contributor.author Семенюг, О. М.
dc.contributor.author Савьолова, Ельвiра Вiкторiвна
dc.contributor.author Maevsky, Dmitry
dc.contributor.author Semenug, A. M.
dc.contributor.author Yakovlev, O. V.
dc.contributor.author Morozov, O. P.
dc.contributor.author Topuzanov, O. O.
dc.contributor.author Savolova, Elvira
dc.contributor.author Маевский, Дмитрий Андреевич
dc.contributor.author Семенюг, А. Н.
dc.contributor.author Яковлев, А. В.
dc.contributor.author Морозов, А. П.
dc.contributor.author Топузанов, А. А.
dc.contributor.author Савёлова, Эльвира Викторовна
dc.date.accessioned 2018-08-10T08:04:37Z
dc.date.available 2018-08-10T08:04:37Z
dc.date.issued 2018-02
dc.identifier.citation Експериментальні дослідження взаємних впливів між провідниками трифазного кабелю / Д. А. Маевський, О. М. Семенюг, О. В. Яковлев, О. П. Морозов, О. О. Топузанов, Е. В. Савьолова // Електротехн. та комп’ютерні системи : наук.-техн. журн. – 2018. – № 27 (103). – С. 24–35. uk
dc.identifier.issn 2221-3805
dc.identifier.uri http://etks.opu.ua/?fetch=articles&with=info&id=957
dc.identifier.uri http://dspace.opu.ua/jspui/handle/123456789/7895
dc.description.abstract Наведено результати експериментальних досліджень взаємних впливів між проводами трифазного броньованого кабелю ВБбШвнг 0,66 кВ. Дослідження полягало в визначенні амплітудно-частотної характеристики кабелю при зміні частоти синусоїдальної напруги в діапазоні від 50 Hz до 100 kHz. Визначено первинні параметри кабелю та виконано математичне моделювання процесів в кабелі за раніш створеною математичною моделлю. Результати експерименту підтверджують правильність моделі та свідчать про наявність суттєвих взаємних впливів між провідниками кабелю навіть на низьких частотах. en
dc.description.abstract The article presents the results of experimental studies of mutual influences between the wires of the “ВБбШвнг” three-phase armored cable of 0.66 kV. The purpose of this study is to check the mathematical model of propagation of currents and voltages in power electric cables created by the authors. The main difference between this model and existing one is the consideration of mutual electric and magnetic influences between the cable conductors. A voltage with an effective value of 2V (active conductor) was applied to one of the conductors of the cable (conditionally - phase A) from the sinusoidal waveform generator. When the oscillator frequency was varied from 50 Hz to 100 kHz, this voltage was maintained the same. Two other conductors (conditionally - phase B and C) are not connected (passive conductors). The effective value of the voltage at the end of the active and passive conductors was measured in two load modes - idle and in symmetrical active load mode of 10 Ohm. The effective value of the current at the input of the active conductor was also measured. The frequency response of the cable was determined. The primary parameters of the cable are calculated and mathematical modeling of the processes in the cable is performed according to the previously created mathematical model. The experimental results with an accuracy of about 8% correspond to the results of the experiment. Thus, the experiment demonstrates the correctness of the model and shows the presence of significant mutual influences between the cable conductors even at low frequencies. So, in the idle mode at 50 Hz, the voltage on the passive conductor has a value of 10% of the voltage on the active conductor. And at high frequencies the wobble increases and at 100 kHz the voltage on the passive conductor exceeds the voltage on the active one by 1.1 times. This excess arises from the imposition of incident and reflected waves in the conductors of the cable. The results of all experiments are presented in the article. en
dc.description.abstract Приведены результаты экспериментальных исследований взаимных влияний между проводами трехфазного бронированного кабеля ВБбШвнг 0,66 кВ. Исследование проведено при изменении частоты синусоидального напряжения в диапазоне от 50 HZ до 100 kHZ. Определены первичные параметры кабеля и выполнено математическое моделирование процессов в кабеле по ранее созданной математической модели. Результаты эксперимента подтверждают правильность модели и свидетельствуют о наличии существенных взаимных влияний между проводниками кабеля. Показано, что наличие взаимных влияний приводит к искажению формы сигнала на выходе кабеля (на входе нагрузки) по отношению к форме сигнала на входе (после ШИП). Это позволило сделать вывод о невозможности применения длинных кабельных линий в частотно-управляемом электроприводе. en
dc.language.iso uk en
dc.publisher Одес. нац. политехн. ун-т. – Одеса: Астропринт
dc.subject трифазний кабель en
dc.subject електромагнітна сумісність en
dc.subject взаємні впливи en
dc.subject частотнорегульований електропривод en
dc.subject амплітудно-частотна характеристика en
dc.subject електромагнітні завади en
dc.subject three-phase cable en
dc.subject mutual influences en
dc.subject electromagnetic compatibility en
dc.subject frequency-regulated electric drive en
dc.subject electromagnetic interference en
dc.subject трехфазный кабель en
dc.subject взаимные влияния en
dc.subject электромагнитная совместимость en
dc.subject частотно-регулируемый электропривод en
dc.subject электромагнитные помехи en
dc.title Експериментальні дослідження взаємних впливів між провідниками трифазного кабелю en
dc.title.alternative Experimental study of the mutual influences between the three phase cable's wires en
dc.title.alternative Экспериментальные исследования взаимных влияний между проводниками трехфазного кабеля en
dc.type Article en
opu.kafedra Кафедра теоретичних основ і загальної електротехніки
opu.citation.journal Електротехнічні та комп’ютерні системи en
opu.citation.firstpage 24 en
opu.citation.lastpage 35 en
opu.citation.issue № 27 (103) en
opu.staff.id dmitry.a.maevsky@opu.ua
opu.staff.id yakovlev.o.v@opu.ua
opu.staff.id savolova.ev@opu.ua


Файлы, содержащиеся в элементе

Этот элемент содержится в следующих коллекциях

Показать сокращенную информацию