eONPUIR

Енергетичні показники електроприводів кранових механізмів підйому

Показать сокращенную информацию

dc.contributor.author Савич, С. П.
dc.contributor.author Ярмолович, В. Я.
dc.contributor.author Орлик, В. В.
dc.contributor.author Савьолова, Е. В.
dc.contributor.author Savich, S. P.
dc.contributor.author Yarmolovich, V. Ya.
dc.contributor.author Orlik, V. V.
dc.contributor.author Savolova, E. V.
dc.contributor.author Савич, С. П.
dc.contributor.author Ярмолович, В. Я.
dc.contributor.author Орлик, В. В.
dc.contributor.author Савёлова, Э. В.
dc.date.accessioned 2018-08-10T10:33:28Z
dc.date.available 2018-08-10T10:33:28Z
dc.date.issued 2018-03
dc.identifier.citation Енергетичні показники електроприводів кранових механізмів підйому / С. П. Савич, В. Я. Ярмолович, В. В. Орлик, Е. В. Савьолова // Електротехн. та комп’ютерні системи. – 2018. – № 27 (103). – С. 157–164. uk
dc.identifier.issn 2221-3805
dc.identifier.uri http://etks.opu.ua/?fetch=articles&with=info&id=973
dc.identifier.uri http://dspace.opu.ua/jspui/handle/123456789/7902
dc.description.abstract Проведено порівняння споживання електроенергії різними типами електроприводів для кранових механізмів підйому: реостатне регулювання, електроприводи ПН-АД і ПЧ-АД. При цьому проводились розрахунки для конкретного механізму з заданим певним режимом роботи. Дослідження довели, що для заданого режиму роботи термін окупності частотного перетворювача складає 3,5-5,5 років en
dc.description.abstract The operational quality of the work of crane mechanisms, their performance, as well as the problem of energy conservation largely depends on the electric drive. Industrial electric drive consumes 60-70% of all electric power produced according to various estimates. In connection with the increase in electricity prices and the limited capacity to increase the power generating units, the problem of reducing electricity consumption is an urgent task. The purpose of the work is to compare electricity losses during the operation of an asynchronous electric drive with a voltage converter and with a frequency converter with and without recovery of electric energy. In order to achieve this goal, an analysis of electricity consumption during the operation of various electric drives was carried out. With the help of the automated system, the calculation of electricity consumption was performed using different electric drives for crane lifting mechanisms. The automated system of comparison of technical and economic efficiency of asynchronous electric drives of crane mechanisms allows to promptly conclude that it is expedient to use an optimal electric drive in the specific conditions of operation of a crane mechanism. Due to the unification of approaches to the analysis of operating modes of lifting mechanisms, the program calculates the losses of electricity in static and dynamic modes. The program calculates the potential energy savings and payback period of the electric drive, taking into account the load, moments of inertia and relative time with reduced speeds. Considering separate alternative electric drives of lifting mechanisms came to the conclusion. Electricity consumption by asynchronous motors of crane mechanisms depends not only on the type of electric drive, but also on the features of the technological process and modes of their operation. With an increase in the power of the electric motor there is a relatively less power saving in the transition to more complex electric drives. The electric drive with a voltage converter consumes more electricity in all modes compared to rheostatic regulation. It is shown that at low speeds with reduced speeds, an electric drive with a frequency converter without a recuperator consumes more electricity than an electric drive with a rheostatic control. en
dc.description.abstract Проведено сравнение потребления электроэнергии разными типами электроприводов для крановых механизмов подъема: реостатное регулирование, электроприводы ПН-АД и ПЧ-АД. При этом проводились расчеты для конкретного механизма с заданным определенным режимом работы. Исследования показали, что при незначительном времени работы со сниженными скоростями электропривод с преобразователем частоты без рекуператора потребляет больше электроэнергии, чем электропривод с реостатным регулированием. en
dc.language.iso uk en
dc.publisher Одес. нац. политехн. ун-т. – Одеса: Астропринт
dc.subject електропривод en
dc.subject автоматизована система техніко-економічного порівняння en
dc.subject реостатне керування en
dc.subject перетворювач напруги en
dc.subject перетворювач частоти en
dc.subject electric drive en
dc.subject automated system of technical and economic comparison en
dc.subject rheostat control en
dc.subject voltage converter en
dc.subject frequency converter en
dc.subject электропривод en
dc.subject автоматизированная система технико-экономическое сравнение en
dc.subject реостатное регулирование en
dc.subject преобразователь напряжения en
dc.subject преобразователь частоты en
dc.title Енергетичні показники електроприводів кранових механізмів підйому en
dc.title.alternative Energy indicators of electric drive of crane lifting mechanisms en
dc.title.alternative Энергетические показатели электроприводов крановых механизмов подъема en
dc.type Article en
opu.kafedra Кафедра електропостачання та енергетичного менеджменту
opu.kafedra Кафедра теоретичних основ і загальної електротехніки
opu.citation.journal Електротехнічні та комп’ютерні системи en
opu.citation.firstpage 157 en
opu.citation.lastpage 164 en
opu.citation.issue № 27 (103) en
opu.staff.id savich.s.p@opu.ua